RESPONSE MODIFICATION FACTOR IN REINFORCED CONCRETE SPECIAL MOMENT RESISTING FRAME BUILDINGS
| dc.contributor.advisor | Dr. Haitham Ayyad | |
| dc.contributor.author | Majdi Osama Ahmaro | |
| dc.date.accessioned | 2026-11-26T11:09:56Z | |
| dc.date.issued | 2026-11 | |
| dc.description | number of Page: 170P | |
| dc.description.abstract | The response modification factor R = 8 that ASCE 7-16 assigns to reinforced concrete (RC) special moment-resisting frames is a single value, applied regardless of height, period or detailing. This study estimates the factor for seven three-dimensional frames designed to ASCE 7-16 and detailed to ACI 318-19, for a rock site with the hazard of seismic Zone 3 of Palestine (Z = 0.30): frames of four, six and fifteen stories, and four variants of the fifteen-story frame (wider hoop spacing with lower concrete strength, higher column reinforcement, and reduced column sections at two locations). The frames were designed in ETABS and analyzed by pushover analysis in SAP2000, with the hinge properties and acceptance criteria of ASCE 41-17. The factor was computed as R = Rμ × Ω from an equal-area bilinear idealization, under three code-based definitions of the maximum displacement: the amplified displacement of ASCE 7-16 (Method A), the target displacement of FEMA 356 (Method B), and the displacement at which the first component reaches the Collapse-Prevention limit of ASCE 41-17 (Method C). Because the prototype is in Risk Category III, the estimated factor is R / Ie and is compared with 8 / 1.25 = 6.40. Methods A and B give 3.30 to 4.19 and 2.24 to 3.74, below 6.40, because their demand displacements are only 1.1 to 1.6 times the effective yield displacement. Method C gives 10.21 to 13.50, above 6.40 in every model, with ductility ratios of 1.99 to 2.92; under the first-mode load pattern the five models that reached the limit give 9.98 to 11.08. Wider hoop spacing with lower concrete strength lowered the capacity-based factor by 12.1 percent, higher column reinforcement raised it by 9.5 percent, and reducing column sections away from the first story changed it by less than 0.5 percent. For the seven frames examined and under the stated assumptions, R = 8 is conservative with respect to the capacity available up to Collapse Prevention, and the estimated factor depends strongly on the definition of the maximum displacement, which should always be stated. Nonlinear dynamic analysis is recommended to confirm these results. | |
| dc.identifier.citation | 2026 | |
| dc.identifier.uri | https://scholar.ppu.edu/handle/123456789/9498 | |
| dc.language.iso | en_US | |
| dc.subject | response modification factor | |
| dc.subject | special moment-resisting frame | |
| dc.subject | pushover analysis | |
| dc.subject | overstrength | |
| dc.subject | displacement ductility | |
| dc.subject | ASCE 7-16 | |
| dc.subject | ASCE 41-17 | |
| dc.subject | ACI 318-19 | |
| dc.subject | collapse prevention. | |
| dc.title | RESPONSE MODIFICATION FACTOR IN REINFORCED CONCRETE SPECIAL MOMENT RESISTING FRAME BUILDINGS | |