dc.description.abstractIn this paper we present the results of power cycling tests of transfer molded, DCB based power components at temperature swings up to 155 K. The results are statistically analysed. The tested components show a power cycling capability approximately 10 times higher as expected from extrapolation of results of standard power modules.en_US