DSpace Repository

Behaviour of corroded shear-critical reinforced concrete beams repaired with NSM CFRP rods

Show simple item record

dc.contributor.author Almassri, Belal
dc.contributor.author Kreit, Amjad
dc.contributor.author Almahmoud, Firas
dc.contributor.author Francois, Raoul
dc.date.accessioned 2018-04-14T07:44:14Z
dc.date.accessioned 2022-05-22T08:29:09Z
dc.date.available 2018-04-14T07:44:14Z
dc.date.available 2022-05-22T08:29:09Z
dc.date.issued 2015
dc.identifier.citation Almassri B, Kreit A, Al Mahmoud F, Francois R. Behaviour of corroded shear-critical reinforced concrete beams repaired with NSM CFRP rods. Composite Structures. 2015 May 1;123:204-15. en_US
dc.identifier.issn 0263-8223
dc.identifier.uri http://localhost:8080/xmlui/handle/123456789/8019
dc.description.abstract This paper discusses the results of an experimental program designed to investigate the effect of repairing the RC corroded shear-critical deep beams with near surface mounted (NSM) carbon fibre-reinforced polymer (CFRP) rods. A 28-year-old RC beam corroded by exposure to a chloride environment was cut into two small short-shear-span beams, along with a control beam of the same characteristics (age, length and cross-section). One RC corroded deep beam was repaired in bending and the other one was repaired in both bending and shear with NSM CFRP rods. Force–displacement curves were plotted for the corroded and control beams. After the beams had been tested up to failure, the loss of mass was measured and plotted for both the longitudinal and transverse reinforcement. The slip of tensile reinforcement at the end of the beams was also measured during the tests. Experimental results show that both corroded and control deep beams repaired only in bending failed due to shear mode of failure (diagonal tension failure), while corroded and control beams repaired in both bending and shear failed due to concrete crushing. The test results also showed that the corrosion of both longitudinal and transversal reinforcement hardly modified the mechanical response of deep beams. en_US
dc.language.iso en_US en_US
dc.publisher Elsevier en_US
dc.relation.ispartofseries Composite Structures;123:204-15.
dc.subject Carbon fibre reinforced polymers Reinforced concrete Corrosion Shear strengthening Shear failure Near surface mounted (NSM) en_US
dc.title Behaviour of corroded shear-critical reinforced concrete beams repaired with NSM CFRP rods en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Browse

My Account