DESIGN OF WASTEWATER COLLECTION SYSTEM FOR BAIT KAHIAL

Show simple item record

dc.contributor.advisor ABU SHARKH , MAJED
dc.contributor.author ABU-AIHOUR, RASHA
dc.contributor.author KAFAFY, NIBAL
dc.contributor.author WARASNH, NADA
dc.date.accessioned 2019-01-14T11:58:42Z
dc.date.accessioned 2022-05-19T12:10:34Z
dc.date.available 2019-01-14T11:58:42Z
dc.date.available 2022-05-19T12:10:34Z
dc.date.issued 2008-06-01
dc.identifier.uri http://localhost:8080/xmlui/handle/123456789/6544
dc.description no of pages 41 , 22128 مباني 15/2008 , in the store
dc.description.abstract There is no wastewater collection system at present in Bait kahil town. The sewage from residential and public buildings in the area is drained to cesspits. These have become clogged with time and require frequent emptying. The continued use of cesspits with the icrease in population will cause environmental and health problem, and may create contamination of the underground water aquifer. Furthermore, emptying csspools constitutes an offensive odor nuisance to the population. On the other hand, emptying the vacuum trunks in the nearly wadi causes negative impacts on the visual landscape. In reference to above description of the existing situation, there is a clear need of project in order to improve the sanitary level in Beit kahil town. The first step is serving the city with wastewater collection system. So, the main objective of this project is to design wastewater collection network for Bait kahil town of the Hebron district. The present study considered the annual population growth and their water consumption for the coming 25 years that will be the design period, along with the commercial and industrial development in the area. The necessary hydraulic calculation needed for the design of the main trunks was carried out by simple calculation. The results of the study show that wastewater disposal in Bait kahil area causes problems to the peoples; subsequently there is a big need for immediate steps for construction of the proposed wastewater collection system. Gravity flow sanitary sewer was proposed for most of Bait kahil areas to minimize the cost of construction and excavations. en_US
dc.language.iso en en_US
dc.publisher جامعة بوليتكنك فلسطين - مباني en_US
dc.subject DESIGN OF WASTEWATER COLLECTION SYSTEM en_US
dc.title DESIGN OF WASTEWATER COLLECTION SYSTEM FOR BAIT KAHIAL en_US
dc.type Other en_US