dc.contributor.advisor |
Alkhateeb, Imad |
|
dc.contributor.author |
Qasrawi, Amjad |
|
dc.contributor.author |
Yasin, Talat |
|
dc.date.accessioned |
2018-12-04T11:01:45Z |
|
dc.date.accessioned |
2022-05-19T11:17:34Z |
|
dc.date.available |
2018-12-04T11:01:45Z |
|
dc.date.available |
2022-05-19T11:17:34Z |
|
dc.date.issued |
2009-06-01 |
|
dc.identifier.uri |
http://localhost:8080/xmlui/handle/123456789/6394 |
|
dc.description |
CD , no of pages 114 , 24846, ميكانيك 18/2009 , in the store |
|
dc.description.abstract |
In order to attain the best energy efficiency in an industrial plant, an energy audit is a prerequisite process for identifying the general energy consumption condition and to hence identify the measures that need to be taken to save the cost of excessive energy consumed and later to retrofit the faults that were observed. The case study presented in this paper is a medium industry plant located in Hebron. The audit methodology, observation, and audit results will be presented and discussed with the recommendation drawn. |
en_US |
dc.language.iso |
en |
en_US |
dc.publisher |
جامعة بوليتكنك فلسطين - كلية الهندسة - ميكانيك |
en_US |
dc.subject |
Energy Auditing |
en_US |
dc.subject |
Industrial Premises |
en_US |
dc.title |
Energy Auditing for an Industrial Premises |
en_US |
dc.type |
Other |
en_US |