dc.description CD, no of pages 111, 30311, 18/2017طاقة, in the store
dc.description.abstract نظرا لزيادة استخدام الكهرباء في كل جزء من الحياة ، وزيادة عدد غير الخطية الأحمال (وليس الكوميديا) التي لا تلتزم الموجه جيبيه التي عرضت عليها والحالات التشويه في الجهد والموجي الحالي في الشبكة الكهربائية الموجودة في. لذلك ، فانه يخلق الكثير من المخاطر الكبيرة مشكله مثل زيادة التوتر والتدفئة علي الكابلات ، تقليل عمر المعدات الكهربائية ، وعطل عمليه الحماية معدات والأحمال الحساسة. لذلك ، فانه من الضروري العثور علي حل لهذه الظاهرة و القضاء علي it.so في هذه الدراسة ، ونحن إصلاح المشاكل التوافقية التي توجد في فلسطين الشبكة الكهربائية للجامعة التقنية. حيث نجمع البيانات ونستعرضها ونحللها مناقشته باستخدام جهاز محلل جوده الطاقة مع بعض البرامج الضرورية والبرمجيات المعايير الدولية التي وفقا لنسبه مقبوله من التوافقي موجود. ثم نجد المشاكل وحلها من خلال تصميم مرشح التوافقي السلبي وتحويله نشطه تصفيه التوافقي ، وقد تم تصميم ومحاكاة العملية التي تقوم بها باستخدام MATLAB برنامج. Due to the increase of using electricity in all part of life, and increase number of non-linear loads (not comics) which does not commit of the sine wave that offered to it and cases distortion in voltage and current waveform in the electrical network that are existing in. So, it creates a lot of significant dangers problem like increase the stress and heating on the cables,decrease the lifetime of the electrical equipment, malfunction the operation of protection equipment and sensitive loads. so, it has necessary to find a solution to this phenomenon and eliminate it.so In this study, we fix the harmonic problems which exist in the Palestine Polytechnic university electrical network. Where we collect the data, review, analyzing and discuss it by using power quality analyzer device with some necessary software programs and the international standards that according the acceptable percentage of harmonic exists. Then we find the problems and solved it by design passive harmonic filter and shunt active harmonic filter, the design and simulation its operation were done by using MATLAB software program. en_US
dc.language English
dc.publisher Palestine Polytechnic University - طاقة en_US
dc.subject Harmonic study,Palestine Polytechnic University, Wadi-Al Haria campus en_US